PT-PS-T100 Electric Installation Measurement Trainer

FEATURES :
  • It is designed to simulate measurement on electrical installation.
  • It is possible to observe and measure for diagnosis or error of an electric installation.
  • Providing training contents such as measuring earth & insulation resistance and load & leakage current.

OPTION

  • Digital Multimeter : 1EA
  • Digital Clamp Meter : 1EA (Including leakage current measurement function)
  • Voltage Detector : 1EA
  • Digital Insulation Meter : 1EA
  • Digital Earth Meter : 1EA
  • Phase Rotation Tester : 1EA

View PDF

Description

TRAINING CONTENTS :
  • Measurement of AC Voltage
  • Measurement of Phase Sequence
  • Voltage Detection
  • Measurement of an Earth Resistance
    – 2 Points & 3 Points
  • Measurement of an Insulation Resistance
  • Measurement of an Insulation Resistance
    – In Washing Machine Block & 3 Phase Motor Block
  • Measurement of a Load Current
  • Measurement of Leakage Current
ACCESSORY :
  • Training Manual : 1 Copy
  • Power Plug L : 1EA
  • Product Cover : 1EA

SPECIFICATION

  • P1, P2, P3 Block
  • PE2 Block
  • Gas Pipe Block
  • Water Pipe Block
  • Radiator Block
  • Size : 720(W) x 580(D) x 150(H)mm

MAIN POWER INPUT BLOCK

  • Type : Circular Connector

3 PHASE MAIN MCCB BLOCK

  • MCCB (3 Phase 4 Wires)

3 PHASE MCCB & 1 PHASE MCCB BLOCK

  • MCCB (3 Phase 3 Wires)/MCCB (1 Phase)
  • Outlet (1 Phase)/Outlet (3 Phase)

3 PHASE MOTOR & MEGA BLOCK

  • 3 Phase Motor Stimulator
  • 3 Phase Motor Mega Select Switch

HEATER PIPE & EV. SELECT BLOCK

  • EV Select Switch

ILLUMINATION BLOCK

  • ELCB/Illumination (Lamp)/Mega Select Switch

LOOP & LOAD, LEAK R, LEAK C BLOCK

  • ELCB/Outlet
  • Select Switch : Load/Leak R/Leak C

WASHING MACHINE BLOCK

  • ELCB
  • Washing Machine Simulator Graphic
  • Human Body Simulator Graphic
  • Mega Select Switch/Leak I VR
  • Safety & Danger Indicator

PE1 & PE SELECT BLOCK

  • PE Select Switch